Advanced Vector Control Inverter
Vector control: 0–320 Hz V/F control: 0–3200Hz 1–16 kHz
The carrier frequency is automatically adjusted based on the load features.
Technology Features
|
Item |
VLF2000 |
|
|
Standard functions |
Control mode |
Sensorless flux vector control (SFVC) Voltage/Frequency (V/F) control |
|
Maximum frequency |
Vector control: 0–320 Hz V/F control: 0–3200Hz |
|
|
Carrier frequency
|
1–16 kHz |
|
|
The carrier frequency is automatically adjusted based on the load features. |
||
|
Input frequency esolution
|
Dgital setting: 0.01 Hz |
|
|
Analog setting: maximum frequency x 0.025% |
||
|
Startup torque
|
G type: 0.5 Hz/150% (SFVC) |
|
|
P type: 0.5 Hz/100% |
||
|
Speed range |
1:100 (SFVC) |
|
|
Speed stability accuracy |
± 0.5% (SFVC) |
|
|
Overload capacity |
G type: 60s for 150% of the rated current, 3s for 180% of the rated current. |
|
|
P type: 60s for 120% of the rated current, 3s for 150% of the rated current. |
||
|
Torque boost
|
Fixed boost |
|
|
Customized boost 0.1%–30.0% |
||
|
V/F curve |
Straight-line V/F curve Multi-point V/F curve |
|
|
N-power V/F curve (1.2-power, 1.4-power, 1.6-power,1.8-power, square) |
||
|
V/F separation |
Two types: complete separation; half separation |
|
|
Ramp mode |
Straight-line ramp S-curve ramp |
|
|
Four groups of acceleration/deceleration time with the range of 0.0–6500.0s |
||
|
DC braking |
DC braking frequency: 0.00 Hz to maximum frequency Braking time: 0.0–100.0s |
|
|
Braking action current value: 0.0%–100.0% |
||
|
JOG control |
JOG frequency range: 0.00–50.00 Hz |
|
|
JOG acceleration/deceleration time: 0.0–6500.0s |
||
|
Standard functions |
Onboard multiple preset speeds |
It implements up to 16 speeds via the simple PLC function or combination of X terminal states |
|
Onboard PID |
It realizes process-controlled closed loop control system easily. |
|
|
Auto voltage regulation (AVR) |
It can keep constant output voltage automatically when the mains voltage changes. |
|
|
Overvoltage/ Overcurrent stall control |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/over current. |
|
|
Torque limit and control |
It can limit the torque automatically and prevent frequent over current tripping during the running process. |
|
|
Instantaneous stop doesn’t stop |
The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time. |
|
|
Rapid current limit |
It helps to avoid frequent over current faults of the AC drive. |
|
|
High performance |
Control of asynchronous motor is implemented through the high-performance current vector control technology. |
|
|
Timing control |
Time range: 0.0–6500.0 minutes |
|
|
Communication methods |
RS485 |
|
|
Running command channel |
Given by the panel, control terminals, |
|
|
Serial communication port,can be switched by many ways |
||
|
Frequency source |
10 kinds of frequency source,given by |
|
|
Digital analog voltage, analog current,Pulse, serial port.can be switched by many ways |
||
|
Auxiliary frequency source |
10 kinds of Frequency source,can easily realize Micro adjustment,frequency Synthesizer |
|
|
Input and output |
Input terminals |
6 digital input terminals, one of which supports up to 100 kHz high-speed pulse input (optional). |
|
2 analog input terminal, one of which only supports 0–10 V voltage input and the other supports 0–10 V voltage input or 4–20 mA current input. |
||
|
Output terminal |
1 digital output terminal 1 relay output terminal |
|
|
1 analog output terminal :that supports 0–20 mA current output or 0–10 V voltage output |
||
|
Operation on the operation panel |
LED display |
It displays the parameters. |
|
Key locking and function selection |
It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function. |
|
|
Protection mode |
Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection. |
|
|
Environment |
Installation location |
Indoor, avoid direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt. |
|
Altitude |
Lower than 1000m (Lower the grades when using higher then 1000m) |
|
|
Ambient temperature |
-10°C ~40°C (Lower the grades if the ambient temperature is between 40°C and 50°C) |
|
|
Humidity |
Less than 95%RH, without condensing |
|
|
Vibration |
Less than 5.9 m/s2 (0.6 g) |
|
|
Storage temperature |
-20°C~60°C |
|

Selection Guide
1.3PH AC380V±15%/1PH AC220V±15%
|
Model |
Rated Output Power (KW) |
Rated Input current (A) |
Rated Output Current (A) |
Motor Power (kW) |
|
1PH/3PH AC 220V -15%~15% |
||||
|
VLF2200-0R4G |
0.4 |
5.4 |
2.5 |
0.4 |
|
VLF2200-0R75G |
0.75 |
7.2 |
5 |
0.75 |
|
VLF2200-1R5G |
1.5 |
10 |
7 |
1.5 |
|
VLF2200-2R2G |
2.2 |
16 |
11 |
2.2 |
|
VLF2200-3R7G |
3.7 |
17 |
16.5 |
3.7 |
|
3PH AC380V±15% |
||||
|
VLF2400-0R4G |
0.4 |
3.4 |
1.2 |
0.4 |
|
VLF2400-0R75G |
0.75 |
3.8 |
2.5 |
0.75 |
|
VLF2400-1R5G |
1.5 |
5 |
3.7 |
1.5 |
|
VLF2400-2R2G |
2.2 |
5.8 |
5 |
2.2 |
|
VLF2400-3R7G/5R5P |
3.7/5.5 |
10/15 |
9/13 |
3.7/5.5 |
|
VLF2400-5R5G |
5.5 |
15 |
13 |
5.5 |
|
VLF2400-7R5P |
7.5 |
20 |
17 |
7.5 |
|
VLF2400-7R5G/11P |
7.5/11 |
20/26 |
17/25 |
7.5/11 |
|
VLF2400-11G/15P |
11/15 |
26/35 |
25/32 |
11/15 |
|
VLF2400-15G/18.5P |
15/18.5 |
35/38 |
32/37 |
15/18.5 |
|
VLF2400-18.5G/22P |
18.5/22 |
38/46 |
37/45 |
18.5/22 |
|
VLF2400-22G/30P |
22/30 |
46/62 |
45/60 |
22/30 |
|
VLF2400-30G/37P |
30/37 |
62/76 |
60/75 |
30/37 |
|
VLF2400-37G/45P |
37/45 |
76/90 |
75/90 |
37/45 |
|
VLF2400-45G/55P |
45/55 |
92/113 |
90/110 |
45/55 |
|
VLF2400-55G |
55 |
113 |
110 |
55 |
|
VLF2400-75P |
75 |
157 |
150 |
75 |
|
VLF2400-75G/90P |
75/90 |
157/180 |
150/176 |
75/90 |
|
VLF2400-90G/110P |
90/110 |
180/214 |
176/210 |
90/110 |
|
VLF2400-110G/132P |
110/132 |
214/256 |
210/253 |
110/132 |
|
VLF2400-132G/160P |
132/160 |
256/307 |
253/300 |
132/160 |
|
VLF2400-160G/185P |
160/185 |
307/355 |
300/340 |
160/185 |
|
VLF2400-185G/200P |
185/200 |
355/385 |
340/380 |
185/200 |
|
VLF2400-200G/220P |
200/220 |
385/430 |
380/420 |
200/220 |
|
VLF2400-220G/250P |
220/250 |
430/468 |
420/470 |
220/250 |
|
VLF2400-250G/280P |
250/280 |
468/525 |
470/520 |
250/280 |
|
VLF2400-280G/315P |
280/315 |
525/610 |
520/600 |
280/315 |
|
VLF2400-315G/350P |
315/350 |
610/665 |
600/640 |
315/350 |
|
VLF2400-350G/400P |
350/400 |
665/700 |
640/690 |
350/400 |
|
VLF2400-400G/450P |
400/450 |
700/800 |
690/790 |
400/450 |
|
VLF2400-450G/500P |
450/500 |
800/865 |
790/860 |
450/500 |

Hot Tags: advanced vector control inverter, China advanced vector control inverter manufacturers, suppliers, factory, Inverter, Small Inverter, High Performance Vector Type Inverter, Advanced Vector Control Inverter, Inverter Controller, General purpose Inverter